Chasing an audio artifact on power loss
subalpinecircuits.comHey cool device!
Seems like it sounds good to, from the demo video.
In hifi amps from 1980-94 or so they implement speaker protection with relays that switch out the speakers before the thump of turning on or off the psu.
I would still use mlcc for the bulk capacitance. Use 12V or 25V ones to not have to worry about voltage bias. You can get quite a lot of capacitance in 0805 these days.
Okay, that’s a good tip! I freaked myself out and didn’t want to make another mistake on the next board, but it would be nice to stick with the MLCC.
its called 'derating' and it happens with voltage and frequency too.
Maintaining a stable DC rail for a brief period of time upon power loss is generally a good idea. As long as the device doesn't remain energized longer than it would take someone to disassemble.
Electrolytic capacitors are the best solution to this problem from an energy density perspective, but they can wear out faster than ceramics.
I wonder if adding a cap to the power in for the system would slow the power off long enough for the mute to kick in?
> Fast forward many months after I actually got around to finishing the next revision of the boards, got them back - everything worked except the voltage spike! It was still there! What!
If nothing drains that capacitor, it'll charge up after a few on/off cycles and never buffer the spike again... (until it randomly drains by itself 6 months from now)
I was confused what an SA-01 was and I googled and it came up Casio SA-01 keyboard. But that's apparently unrelated to this project
https://subalpinecircuits.com/about/
>My name is Drew, I'm an engineer in Vancouver, Canada. I worked at Bandcamp for 13 years and now I build synthesizers and other audio electronics. My first product, SA-01, will be out in early 2027.
TL;DR vibecoder discovers power supply decoupling and fails to reinvent muting circuits.
What about this is vibecoded? And the whole point of the blog is that the DAC daughterboard already has its power management and muting circuit and yet fails under very specific but easily encountered conditions.