Hantek Power Supply Controller

This is an interface to the serial port on Hantek HDP1160V4S power supply. It should work with other HDP10000-series power supplies. buy

ATTENTION

USING THIS CODE MAY DAMAGE YOUR POWER SUPPLY OR CONNECTED DEVICES. USE AT YOUR OWN RISK.

To communicate with the PSU I am using USB-to-RS232 adapter - does not require any drivers on debian linux.

Installation

pip install hantekpsu

Usage

from hantekpsu import PSU
p = PSU(port='/dev/ttyUSB0', baudrate=2400)

Methods

Method Description Return Type
turn_on() Turns on the power supply unit. None
turn_off() Turns off the power supply unit. None
ocp_on() Enables Over Current Protection (OCP). None
ocp_off() Disables Over Current Protection (OCP). None
ovp_on() Enables Over Voltage Protection (OVP). None
ovp_off() Disables Over Voltage Protection (OVP). None
get_model() Gets the model of the PSU. str
get_active_voltage() Gets the active output voltage of the PSU in volts. float
get_active_current() Gets the active output current of the PSU in milliamps. int
get_voltage_limit() Gets the voltage limit setting of the PSU in volts. float
get_current_limit() Gets the current limit setting of the PSU in milliamps. int
get_on_off_status() Returns the on/off status of the PSU. bool
set_output_voltage(v: float) Sets the output voltage of the PSU in volts. None
set_output_current(mA: int) Sets the output current of the PSU in milliamps. None
set_ovp_limit(v: float) Sets the Over Voltage Protection (OVP) limit in volts. None
set_ocp_limit(mA: int) Sets the Over Current Protection (OCP) limit in milliamps. None

Examples

Set voltage to 12V and turn on the power supply:

>>> from hantekpsu import PSU
>>> p = PSU()
>>> p.set_output_voltage(12.0)
>>> p.turn_on()

Development

Requirements

  • python 3.10+
  • poetry

Ensure the device is connected. If using usb-to-rs232 adapter, run lsusb:

$ lsusb
Bus 001 Device 012: ID 0403:6001 Future Technology Devices International, Ltd FT232 Serial (UART) IC

You should also see something similar to /dev/ttyUSB0 in the /dev folder.

To figure out which device it is, you can run ls /dev before plugging in the adapter and after and compare the differences.

Installation

git clone https://github.com/builder555/hantek-controller
cd hantek-controller
poetry config virtualenvs.in-project true --local
poetry install

Unit Tests

When adding new features or modifying existing ones, make sure you add unit tests and run them:

$ poetry run pytest -v

test_psu.py::test_get_model_number PASSED                       [  6%]
test_psu.py::test_get_active_voltage PASSED                     [ 12%]
test_psu.py::test_get_active_current_in_milliamps PASSED        [ 18%]
test_psu.py::test_get_voltage_limit PASSED                      [ 25%]
test_psu.py::test_get_current_limit_in_milliamps PASSED         [ 31%]
test_psu.py::test_get_on_off_status PASSED                      [ 37%]
test_psu.py::test_turn_on PASSED                                [ 43%]
test_psu.py::test_turn_off PASSED                               [ 50%]
test_psu.py::test_ocp_on PASSED                                 [ 56%]
test_psu.py::test_ocp_off PASSED                                [ 62%]
test_psu.py::test_ovp_on PASSED                                 [ 68%]
test_psu.py::test_ovp_off PASSED                                [ 75%]
test_psu.py::test_set_voltage PASSED                            [ 81%]
test_psu.py::test_set_current PASSED                            [ 87%]
test_psu.py::test_set_ovp PASSED                                [ 93%]
test_psu.py::test_set_ocp PASSED                                [100%]

========================= 16 passed in 0.03s =========================

You can also run pytest-watch while developing to run tests automatically on save:

poetry run ptw --runner 'pytest -v'